Skip to content
Request a Quote

Products

One platform. Built to fit your site, not the other way around.

A Sentor site is one controller, the expansion cards it needs, and the software layer that manages it. Sites start with the capacity they require and grow by adding cards to the controller already installed — not by replacing the system.

Controllers

Two generations, one installed base

Current generation

i7000

The i7000 is the current Sentor controller and the model specified for new installations. It succeeds the ST3000 family and was launched under the ST7000 designation.

Ask us for the current i7000 specification sheet when you are sizing a new site.

Earlier generation — fully supported

ST3000

The ST3000 family remains supported. Expansion cards, communications modules, keypads and sensors are still available for installed ST3000 sites, and the specifications below describe that platform.

If you are running ST3000 controllers, nothing needs to be replaced to add capacity or bring a new site online alongside them.

Controller capability

What one controller handles

Sixteen programmable inputs, expandable to eighty. Eight relay outputs, expandable to forty. The sixteen base inputs are split between eight optically isolated digital clean-contact inputs and eight general-purpose inputs configurable as analogue or digital.

Inputs accept clean contact closures, protected loops with end-of-line resistors, 0–30 VDC analogue, 4–20 mA current loops and direct temperature sensors in °C or °F. Analogue inputs are sampled up to twenty times a second at better than 0.5% accuracy.

Outputs are eight single-pole double-throw relays rated at 1 A, plus horn and siren outputs and auxiliary 13 VDC power for driving connected devices.

On board: two RS-232 and two RS-485 ports, X10 power-line carrier connection, a lead-acid backup battery charger, an on-board lithium battery, and tamper switch options. Ethernet and 3G/4G cellular are fitted as options.

Sentor controller with the lid open, showing the motherboard and expansion cards
Wall-mount controller cabinet

Wall mount

ST3000W

Lockable wall cabinet with hinged lid and cable knockouts.

Rack-mount controller

Rack mount

ST3000R

19″ rack enclosure in powder-coated metal for standard equipment racks.

Security housing

ST3000S

Reinforced enclosure with tamper switch for high-security sites. IP65 and IP67 ingress-rated housings are also available.

Expansion hardware

Accessories & modules

Plug in what your site needs — sensing, access control, communications, enclosures or on-site displays. Everything here fits an installed controller without replacing it.

ST317

I/O Expansion Card

Adds 16 programmable inputs (8 digital, 8 analogue) and 8 dry-contact relay outputs per card. Fits inside the existing controller housing; up to 4 per controller.

ST330

Telephone / Voice Card

Landline modem, dial-out to computer, telephone or pager, and alarm announcements in a recorded voice with keypad menus. Allows remote dial-in access.

ST30G

Cellular Modem

Multi-band 3G/4G always-on cellular data with a static IP address, serial-to-ethernet conversion and SSL-encrypted access.

ST301 / ST1100

Serial-to-Network Web Server

Network-enables a controller over LAN or internet. Two models of the same module: RS-232/RS-422/RS-485 to 10Base-T/100Base-TX, 2 MB flash ROM, configurable by internal web server, Telnet or serial.

ST505

Bi-Directional Power Coupler

Real-time forward and reflected power (VSWR) in watts or dBm. Almost zero insertion loss, non-invasive, pre-calibrated to frequency, male or female N connectors.

ST007V / ST007H

LCD Keypad Terminal

Vertical or horizontal heavy-duty backlit LCD terminal. Shows live device readings on site and acts as a security keypad with individual user PINs. Up to 31 per controller.

ST352A

Wiegand Access Interface

Connects card, proximity, fingerprint, iris and other Wiegand readers, supporting up to 64,000 users. A current-generation model is available.

ST9-302

SNMP Board

Attaches up to 48 SNMP devices. Supports SNMP v1, v2 and v3. Runs standalone or as a slave to the controller.

ST025

Temperature Sensor

Two-wire, self-powered from the analogue input. 0 °C to +100 °C, sensing accuracy ±0.4 °C, 91.5 µA supply current.

ST025E

Extended-Range Temperature Sensor

Extended-temperature version of the ST025 for outdoor and plant-room use, on the same two-wire electrical specification.

ST5000

NVR & Camera Kits

Network video recorder and camera kits, managed through SenVision. Eight-channel kits with 32-channel systems available.

ST-PB5

Fingerprint / Keypad Unit

Mini colour fingerprint reader and keypad, supplied in the biometric access package.

Enclosures

Housings

Wall, 19″ rack and reinforced security housings, plus IP65 and IP67 ingress-rated enclosures in powder-coated or stainless steel finish.

Readers

Access Reader Range

Proximity, card swipe, keychain medallion, fingerprint, palmprint, iris and facial recognition readers, connected through the ST352A.

ST450

Expansion Ribbon Cable

Required when fitting more than two expansion cards. Supplied with the card.

Some earlier part numbers have been superseded by current-generation equivalents. Ask us to confirm the current part before you specify, particularly on a tender.

Sensing

What you can wire to a Sentor input

Anything that produces a contact closure, a voltage, a current loop or a temperature output can be connected directly, which usually means existing site instrumentation can be brought in rather than replaced.

The full sensor and accessory list is available to dealers and customers on request.

  • Temperature sensors
  • Smoke and fire detectors
  • Fuel level sensors
  • Water pressure sensors
  • Speed / rev-counter sensors
  • RF couplers
  • ±48 VDC sensors
  • Current sensors
  • Door and window contacts
  • PIR movement detectors
  • Wind sensors
  • Strobe lights
  • Cameras and camera controllers
  • Consoles and site computers
  • Modems and wireless / radio devices
  • Antennas

Software suite

Which one do you actually need?

Every Sentor system runs on SitePRO. Add the others as your network grows.

SoftwareWhat it’s forWho needs it
SitePROGraphical interface to configure and monitor a controller directly — the required base software for every install.Every customer
SenTrendAutomated polling and network management across 5+ sites; downloads logs on a schedule, exports for analysis.Multi-site operators
SentorCloudWeb and mobile dashboard with mapped site locations — view any site’s status from a phone, anywhere.Distributed teams
SenBaseDatabase server that collects and graphs readings across a LAN, and can also be configured to run live on the internet from your own server instead of the Sentor cloud service.On-premise data retention
Message ProSMS, pager and email alerting engine — routes the right alarm to the right person automatically.Automated alerting
SenCheckPushes access-card additions and removals to every site on the network in one action.Multi-site access control
Sentor GeniusCalibration utility for RF couplers and analogue sensors.Install & commissioning

SitePRO is the software referred to in older Sentor documentation as the Sentor GUI, and Message Pro as AMPro — in both cases the same package under an earlier name.

Protocols & integration

Built to fit the systems you already run.

SNMP v1, v2 and v3

For network management integration. The ST9-302 board attaches up to 48 SNMP devices and can run standalone or as a slave to the controller.

DNP3

For utilities, water, oil and gas infrastructure, so Sentor sites report into an existing SCADA master. We confirm the conformance level directly with you when you enquire.

Modbus

Supported. Because the implementation depends on your configuration, contact us for the details that apply to your system.

Building systems

Integrates with Clipsal C-Bus and Honeywell systems already installed in many commercial buildings.

Access control

The Wiegand standard, which most card, proximity and biometric readers support, so readers are not tied to one manufacturer.

Connectivity

Cellular, ethernet and TCP/IP, fibre optic, satellite, radio and microwave, DSL and dial-up. Different sites on one network can use different bearers.

Not sure what configuration you need?

Tell us what you are monitoring and how the site connects, and we will specify it against your actual requirement.